{"id":1076,"date":"2023-04-17T13:57:51","date_gmt":"2023-04-17T05:57:51","guid":{"rendered":"http:\/\/shslcable.com\/?post_type=product&#038;p=1076"},"modified":"2023-12-06T16:51:39","modified_gmt":"2023-12-06T08:51:39","slug":"h05v-k-h07v-k-h03vv-f-h03vv-h2-fh05vv-f-h05vv-h2-f","status":"publish","type":"product","link":"https:\/\/shslcable.com\/index.php\/product\/h05v-k-h07v-k-h03vv-f-h03vv-h2-fh05vv-f-h05vv-h2-f\/","title":{"rendered":"H05V-K H07V-K H03VV-F H03VV H2-FH05VV-F H05VV H2-F"},"content":{"rendered":"<h6 style=\"text-align: center;\"><span style=\"color: #333399;\"><em><strong>CE Power Cord H05V-K And <\/strong><\/em><\/span><span style=\"color: #333399;\"><em><strong>H07V-K<\/strong><\/em><\/span><\/h6>\n<p>&nbsp;<\/p>\n<h6>1. Application<\/h6>\n<p>Used for flexible connections inside electrical appliances, instruments, and electrical devices. Connection between instruments, devices, distribution boards, power distributors (boards), and telecommunications equipment, also suitable for dry protection systems (grounding wires) and alarm lights. <em> Used in damp and oil-water mixed places, Used for electrical appliances, instruments, power equipment, and automation devices, with no forced traction, no direction, and movable connecting wires inside and outside.\u00a0<\/em><\/p>\n<h6>2. Cable Structure<\/h6>\n<p>Conductor: Single or stranded bare copper or tinned copper wire in accordance with IEC60228VDE 0295 Class5 standard<br \/>\nInsulation: PVC\/TI1 according to DIN VDE 0281 Part 1+HD21.1<br \/>\nColor code: The wire core is identified by color and complies with HD402 standard<br \/>\nApplication standards: HD21.3 S3, VDE-0281 Part-3, CE Low Voltage Directive, 73\/23\/EEC, and 93\/68\/EEC<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-1077\" src=\"https:\/\/shslcable.com\/wp-content\/uploads\/2023\/04\/H07V-K-CABLE1.gif\" alt=\"H05V-K H07V-K H03VV-F H03VV H2-FH05VV-F H05VV H2-F \" width=\"750\" height=\"750\" \/><\/p>\n<h6>3. Technical Parameter<\/h6>\n<p>Rated voltage: 30OV\/500V<br \/>\nTest voltage: 2000V in accordance with DIN VDE0281 Part 2+HD21.2<br \/>\nMinimum bending radius fixed laying: 12.5XD (cable outer diameter)<br \/>\nMobile installation: 12.5XD (cable outer diameter)<br \/>\nFixed laying temperature range: -30 to+80 \u2103<br \/>\nMobile installation: -5 to+70 \u2103<br \/>\nFlame retardancy: flame retardant and self-extinguishing<br \/>\nComplies with IEC60332-1-2+EN60332-1-2 ULvW-1+CSA FT1<br \/>\nInsulation resistance: 10MQ x km<\/p>\n<h6>4. Characteristics and Compliance<\/h6>\n<p>Characteristics: Solid single core wire,easy to peel,cut,easy to install,in line with the EU standard<\/p>\n<h6 style=\"text-align: center;\"><span style=\"color: #333399;\"><em><strong>CE Power Cord H03VV-H2-F And H03VV-F<\/strong><\/em><\/span><\/h6>\n<h6>1. Application<\/h6>\n<p>Used for flexible connections inside electrical appliances, instruments, and electrical devices. Connection between instruments, devices, distribution boards, power distributors (boards), and telecommunications equipment, also suitable for dry protection systems (grounding wires) and alarm lights.<\/p>\n<h6>2. Data Reference<\/h6>\n<p>Conductor: Single or stranded bare copper or tinned copper wire VDE 0281 Part 5, HD21.5S3 IEC 227-5<br \/>\nInsulation: PVC\/TI2 PVC according to DINVDE0281 Part 1+HD21.1<br \/>\nColor code: The wire core is identified by color and should comply with HD402 standard<br \/>\nSheath material: PVC\/TM2 type polyvinyl chloride<br \/>\nSheath color: black (RAL9005)<br \/>\nApplication standards:&lt;HAR&gt;HD21.5 S3, VDE-0281 Part-5, CE low voltage directive, 73\/23\/EEC&amp;93\/68\/EEC. IEC 60227-5<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-1078\" src=\"https:\/\/shslcable.com\/wp-content\/uploads\/2023\/04\/H07V-K-CABLE2.gif\" alt=\"H03VV H2-F CABLE\" width=\"750\" height=\"750\" \/><\/p>\n<h6>3. Technical Parameter<\/h6>\n<p>Rated voltage: 30OV\/300V<br \/>\nTest voltage: 2000V in accordance with DIN VDE0281 Part 2+HD21.2<br \/>\nMinimum bending radius fixed laying: 4XD (cable outer diameter)<br \/>\nMobile installation: 7.5XD (cable outer diameter)<br \/>\nFixed laying temperature range: -40 to+70 \u2103<br \/>\nMobile installation: -5 to+70 \u2103<br \/>\nFlame retardancy: flame retardant and self-extinguishing<br \/>\nComplies with IEC60332-1-2+EN60332-1-2 ULvW-1+CSA FT1, IEC60332.1<br \/>\nInsulation resistance: 20MQ x km<\/p>\n<h6>4. Characteristics and Compliance<\/h6>\n<p>Characteristics: Conforming to EU coordinated standards; Ultrafine conductor with soft and small bending angle<br \/>\nFlat structure, economical and space saving, capable of withstanding certain mechanical external forces<\/p>\n<h6 style=\"text-align: center;\"><span style=\"color: #333399;\"><em><strong>CE Power Cord H05VV H2-F And <\/strong><\/em><\/span><span style=\"color: #333399;\"><em><strong>H05VV-F<\/strong><\/em><\/span><\/h6>\n<h6>1. Application<\/h6>\n<p>Used for electrical appliances, instruments, power equipment, and automation devices, with no forced traction, no direction, and movable connecting wires inside and outside. Used in damp and oil-water mixed places.<\/p>\n<h6>2. Cable Structure<\/h6>\n<p>Conductor: Single or stranded bare copper or tinned copper wire VDE 0281 Part 5, HD21.5S3 IEC 227-5<br \/>\nInsulation: PVC\/TI2 PVC according to DINVDE0281 Part 1+HD21.1<br \/>\nColor code: The wire core is identified by color and should comply with HD402 standard<br \/>\nSheath material: PVC\/TM2 type polyvinyl chloride<br \/>\nSheath color: black (RAL9005)<br \/>\nApplication standards:&lt;HAR&gt;HD21.5 S3, VDE-0281 Part-5, CE low voltage directive, 73\/23\/EEC&amp;93\/68\/EEC. IEC 60227-5<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-1079\" src=\"https:\/\/shslcable.com\/wp-content\/uploads\/2023\/04\/H07V-K-CABLE3.gif\" alt=\"H05VV H2-F And H05VV-F\" width=\"750\" height=\"750\" \/><\/p>\n<h6>3. Technical Parameter<\/h6>\n<p>Rated voltage: 30OV\/500V<br \/>\nTest voltage: 2000V in accordance with DIN VDE0281 Part 2+HD21.2<br \/>\nMinimum bending radius fixed laying: 4XD (cable outer diameter)<br \/>\nMobile installation: 7.5XD (cable outer diameter)<br \/>\nFixed laying temperature range: -40 to+70 \u2103<br \/>\nMobile installation: -5 to+70 \u2103<br \/>\nFlame retardancy: flame retardant and self-extinguishing<br \/>\nComplies with IEC60332-1-2+EN60332-1-2 ULvW-1+CSA FT1, IEC60332.1<br \/>\nInsulation resistance: 20MQ x km<\/p>\n<h6>4. Characteristics and Compliance<\/h6>\n<p>Characteristics: Conforming to EU coordinated standards; Ultrafine conductor with soft and small bending angle. Flat structure, economical and space saving, capable of withstanding certain mechanical external forces<\/p>\n<h6>5. MOQ: 5000M<\/h6>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p><em>Applicable to the cables and wires of rated yolatage 450\/750V and less than 450\/750V AC for power plant, household electrical application,insurment and telecommunication equipment.\u00a0<\/em><\/p>\n","protected":false},"featured_media":1080,"comment_status":"open","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":""},"product_cat":[36],"product_tag":[],"_links":{"self":[{"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/product\/1076"}],"collection":[{"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/comments?post=1076"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/media\/1080"}],"wp:attachment":[{"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/media?parent=1076"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=1076"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/shslcable.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=1076"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}