EN Halogen Free Solar Cable

AC & DC transmission power cables for photovoltaic generating system is designed according to the peculiarambient conditions and requirements, to per form the function of electricity transmission and conversion, for Photovoltaic Generating Equipment

Download
Datasheet

1.Application

This series of PV cable meet with the peculiar requirements of photovoltaic generating plantable for the zoneof high temperature, cold, grassland, moisture, salty fog, strong UV radiation, ozone and etc. Also in considerationof anti-compact, tensile, animals bite, andin high building…etc.

Solar Halogen-free cables for solar photovoltaic power generation equipment are designed based on the special environmental conditions in which photovoltaic power generation equipment is located, and are mainly suitable for DC voltage terminals, outgoing connections of power generation equipment, and bus connections between components. These products are based on the most advanced photovoltaic cable standard in the world, EN50618:2014.

solar cables

2. Model and Name

Model: HIZ2Z2-K

Name: halogen free cable for photovoltaic equipment

Applicable standard: EN50618: 2014

3. Technical Data

 Table1: Current carrying capacity of photovoltaic cables

Sectional cross area (mm2)

Installation method for current carrying capacity
Direct installationInstallation of
single cable

Installation
of dual cables

1 .5

302924
2.54139

33

4

555244
67067

57

10

989379
16132125

107

25

176167142
35218207

176

50

276262221
70347330

278

95

416395333
120488464

390

150

566538453
185644612

515

240

775736

620

Note:Ambient temperature: 60c ( please see table 4 for other ambient temperature), highest temperature of conductor:120C

Table2: Size and Insulation Resistances

Number of conductors
and nominal cross sectional area (mm2)
Thickness of insulation
layer (mm)
Thickness of
sheath (mm)
Upper average limit of outer diameter (mm)Mini insulation resistance at 20℃(MΩ.Km)Mini insulation
resistance at 90℃ (MΩ.Km)
1 X 1.50.70.85.48590.859
1 x 2.50.70.85.96910.691
1 x 40.70.86.65790.579
1 x 60.70.87.44990.499
1 x 100.70.88.84240.424
1 x 160.70.910.13420.324
1 x 250.9112.53390.399
1 x 350.91.1142870.287
1 x 5011.216.32680.268
1 X 701.11.218.72470.247
1 x 951.11.320.82200.22
1 x 1201.21.322.82210.221
1 x 1501.41.425.52060.206
1 x 1851.61.628.52000.2
1 x 2401.71.732.11980.198

Table3: The conversion factor of rated current under different ambient temperature

Ambient Temperature℃Conversion factor
up to 601
700.92
800.84
900.75

Table4: Impact test data

Cable diameter (D) mmWeight of hammerWeight of middle steel sheetHeight mm
D<151000200100
15<D< 151500200150
D>252000200200
4. PV Cable Characteristics

Ambient Temperature : – 40℃ – 90℃
Highest Cable Temperature: 120℃

Insulation Res i stance : > 1859 – 200MΩ .km at 20c,   >0.859-0.200MΩ .km at 90c
Rated voltage: UO/U = 600V/ 1000V AC, 1500V DC (conductor, conductor, unearthing system)
Test voltage : 6500V, 50Hz / 5min or 15000V DC ;

Long time DC withstand voltage: 240h, 1. 5KV at 85℃Surface resistance of sheath: >109MΩ;
Smoke density: Light transmittance > 60%

Operate under high temperature, not melt down, not flow;
Pass the test of burning single cable as per IEC 60332-2 – 1

Heat withstand, cold resistant, anti – abrasive, anti -UV, ozone resistant
High medianical strength, acid and alkali resistant, chemical products resistant

Service life up to 25 years
Short circuit temperature: 5sec, 200CC