0.6/1kV STA Armored Copper Power Cable

The armoured cable are mainly used for power distribution in power stations, industrial installation and switchgears, as well as in local mains. Apply to shafts, water and soil, able to bear the larger positive pressure.

Download
Datasheet

0.6/1kV STA Armored Copper Power Cable
1.Application

The cable is used in electric transmission and disirbution system operating at rated voltage of 0.6/1,  1.8/3, 3.6/6, 6/6, 6/10,  8.7/10. 8.7/15, 12/20, 18/30,  21/35, 26/35kV.

This standard also covers their accessories. The cables must have an extruded solid insulation and may contain longitudinal water-blocking properties such as swellable tapes and powders if the installation conditions demand it.

The armoured cable are mainly used for power distribution in power stations, industrial installation and switchgears, as well as in local mains. Apply to shafts, water and soil, able to bear the larger positive pressure. Able to bear certain traction during installation. For fixed installation underground, in interior premises, cable ducts, in the open air and in water if no risk of any mechanical damage is to be expected. Laying single core cable in magnetic ducts is not allowed.

2. Model and Name
3. Standard
IEC 60502-2 CABLE
It should be noted that IEC 60502-2 excludes cables for special conditions such as those manufactured for use in overhead lines, mining, nuclear power plants, marine and submarine applications. Where this is the case, technical specifications refer to cables being manufactured ‘Generally to IEC 60502-2’.
This Standard is divided into the following parts:
  1. 1kV to 3kV
  2. 6kV to 30kV
  3. Reserved for future development
  4. Test requirements on accessories for cables with a voltage rating from 6kV to 30kV
SCOPE OF IEC 60505-1
Part 1 of this international Standard specified the construction, dimensions and test requirements of cables with extruded solid insulation with a rated voltage ranging between 1kV and 3kV for fixed installations such as distribution networks or industrial installations. Some of the cables covered by IEC 60502 have flame spread-reducing or Low Smoke Zero Halogen (LSZH) properties when exposed to fire.
IEC 60502-1 SYSTEMS CATEGORIES(Operating Conditions)
  • A: Systems in which any phase conductor that comes in contact with earth or an earth conductor is disconnected from the system within 1 minute
  • B: Systems which, under fault conditions, are operated for a short time with one phase earthed (not exceeding 8hrs on any occasion and no more than 125hrs per annum)
  • C: All systems which do not fall into category A or B
IEC 60502-1 CABLE PROPERTIES
A: Insulated Compounds:

Thermoplastic – intended for cables with voltage rating smaller or equal to 3kV

Polyvinly Chloride (PVC)
Thermosetting
Ethylene Propylene Rubber or similar (EPR or EPDM)
High modulus or hard grade ethylene propylene rubber (HEPR)
Cross-linked Polyethylene (XLPE)
B: Sheathing compounds
Thermoplastic: Polyvinyl Chloride (PVC), Polyvinyl Chloride (PVC), Polyethylene (PE), Halogen-Free
Elastomeric: Polychloroprene, Chlorosulphonated polyethylene, Polymers similar to above
C: Conductor
Class 1 or Class 2: Plain, Metal-coated annealed copper, Plain aluminium, Aluminium alloy
Class 5: Plain, Metal-coated copper according to IEC 60228
Some cables meeting the requirements of IEC 60502 benefit from armoured layers, making them able to withstand a higher degree of mechanical stress than comparative sized unarmoured cables. Various types of armour are specified, such as concentric copper wire screens and/or helically wound copper tape as required in the N2XCH cable.

INTERNATIONAL POWER CABLES

Shanghai Pudong Wire and Cable Group is a leading supplier of power cables to British, European and international standards, including IEC 60502. For technical support with your IEC standard cable requirements, contact our technical engineers who have vast experience with their designs, manufacture and testing.

Cores and Corss Section Area:

2 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
2×40.71.22×0.21.8154334.613.5
2×60.71.22×0.21.8165003.083.5
2×100.71.22×0.21.8196731.833.5
2×160.71.42×0.21.8218571.153.5
2×250.91.42×0.21.82411730.7273.5
2×350.91.62×0.21.82514490.5243.5
2×5011.62×0.21.82618770.3873.5
2×701.11.82×0.21.82724540.2683.5
2×951.11.82×0.21.93024830.1933.5
2×1201.222×0.223342130.1533.5
2×1501.422×0.52.23850870.1243.5

3 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
3×1.50.712×0.21.51327312.13.5
3×2.50.712×0.21.5143217.413.5
3×40.71.22×0.21.5153904.613.5
3×60.71.22×0.21.5164713.083.5
3×100.71.42×0.21.5186221.833.5
3×160.71.42×0.222210051.153.5
3×250.91.62×0.222513710.7273.5
3×350.91.62×0.222717240.5243.5
3×5011.82×0.223022470.3873.5
3×701.11.82×0.22.53530230.2683.5
3×951.122×0.52.53938250.1933.5
3×1201.222×0.52.54246420.1533.5
3×1501.422×0.534857670.1243.5
3×1851.62.22×0.535168950.09913.5
3×2401.72.22×0.535686170.07543.5
3×3001.82.22×0.5359109280.06013.5
3×40022.22×0.53.261135560.0473.5

4 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
4×40.712×0.21.5164544.613.5
4×60.712×0.21.5175573.083.5
4×100.712×0.22207911.833.5
4×160.712×0.222312101.153.5
4×250.912×0.222716720.7273.5
4×350.912×0.222921270.5243.5
4×50112×0.223328020.3873.5
4×701.11.22×0.22.53837850.2683.5
4×951.11.22×0.52.54248290.1933.5
4×1201.21.42×0.534760330.1533.5
4×1501.41.42×0.535273560.1243.5
4×1851.61.62×0.535688060.09913.5
4×2401.71.62×0.5362111820.07543.5
4×3001.81.72×0.53.164141760.06013.5
4×40021.72×0.53.569178150.0473.5

5 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
5×40.712×0.21.517.15884.613.5
5×60.712×0.21.519.47203.083.5
5×100.712×0.2222.910141.833.5
5×160.712×0.2225.813921.153.5
5×250.912×0.2230.520020.7273.5
5×350.912×0.2233.725810.5243.5
5×50112×0.5238.637220.3873.5
5×701.11.22×0.52.543.448970.2683.5
5×951.11.22×0.52.548.663380.1933.5
5×1201.21.42×0.5354.478510.1533.5
5×1501.41.42×0.5360.196610.1243.5
5×1851.61.62×0.5366.7117700.09913.5
5×2401.71.62×0.5374.7149000.07543.5
5×3001.81.72×0.53.183.2180000.06013.5

3+1 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
3×4 + 1×2.50.712×0.21.5164434.613.5
3×6 + 1×40.712×0.21.5175313.083.5
3×10 + 1×60.712×0.22207411.833.5
3×16 + 1×100.712×0.222311351.153.5
3×25 + 1×160.912×0.222615560.7273.5
3×35 + 1×160.912×0.222818960.5243.5
3×50 + 1×25112×0.223125180.3873.5
3×70 + 1×351.11.22×0.22.53632930.2683.5
3×95 + 1×501.11.22×0.52.54043490.1933.5
3×120 + 1×701.21.22×0.52.54453650.1533.5
3×150 + 1×701.41.42×0.534964680.1243.5
3×185 + 1×951.61.42×0.535278540.09913.5
3×240 + 1×1201.71.62×0.53.56898140.07543.5
3×300 + 1×1501.81.72×0.53.571127810.06013.5
3×400 + 1×24021.72×0.53.576163590.0473.5

3+2 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
3×4 + 2×2.50.712×0.21.517.58554.613.5
3×6 + 2×40.712×0.21.518.910093.083.5
3×10 + 2×60.712×0.2221.614611.833.5
3×16 + 2×100.712×0.2224.618771.153.5
3×25 + 2×160.912×0.2228.725830.7273.5
3×35 + 2×160.912×0.2230.730010.5243.5
3×50 + 2×35112×0.2236.243920.3873.5
3×70 + 2×351.11.22×0.22.540.355190.2683.5
3×95 + 2×501.11.22×0.52.544.975430.1933.5
3×120 + 2×701.21.22×0.52.550.392030.1533.5
3×150 + 2×701.41.42×0.5354104850.1243.5
3×185 + 2×951.61.42×0.5360.2139450.09913.5
3×240 + 2×1201.71.62×0.53.567.2156430.07543.5
3×300 + 2×1501.81.72×0.53.575.2182040.06013.5

4+1 Cores Steel Tape Armored Power Cable

Nom. Cross-section of conductorInsulation ThicknessInner Covering ThicknessSteel Tape ThicknessSheath ThicknessApprox. O.D.Approx WeightMax. D.C. Resistance
of Conductor (20°C)
Test Voltage A.C
mm2mmmmmmmmmmkg/kmΩ/kmkV/5min
4×4 + 1×2.50.712×0.21.518.45654.613.5
4×6 + 1×40.712×0.21.519.86923.083.5
4×10 + 1×60.712×0.2222.89531.833.5
4×16 + 1×100.712×0.2225.813181.153.5
4×25 + 1×160.912×0.2230.418770.7273.5
4×35 + 1×160.912×0.2234.123240.5243.5
4×50 + 1×25112×0.2238.734150.3873.5
4×70 + 1×351.11.22×0.52.544.244320.2683.5
4×95 + 1×501.11.22×0.52.549.857470.1933.5
4×120 + 1×701.21.22×0.52.555.471120.1533.5
4×150 + 1×701.41.42×0.5360.185560.1243.5
4×185 + 1×951.61.42×0.5366.9105100.09913.5
4×240 + 1×1201.71.62×0.53.574.8132320.07543.5
4×300 + 1×1501.81.72×0.53.578.4164520.06013.5