CE Power Cord Cable H05V-R H07V-R
CE Power Cord H05V-R
1. Application
Internal peripheral connecting wires between distribution boards and power distribution boards for electrical appliances and devices, as well as interfaces between electronic and electrical equipment and switchgear. Designed to use dry semi exposed and embedded conduits that can be bent several times with grounding wires
2. Cable Structure
Conductor: Single or stranded bare copper or tinned copper wire in accordance with IEC60228VDE 0295 Class5 standard
Insulation: PVC/TI1 according to DIN VDE 0281 Part 1+HD21.1
Color code: The wire core is identified by color and complies with HD402 standard
Application standards: HD21.3 S3, VDE-0281 Part-3, CE Low Voltage Directive, 73/23/EEC, and 93/68/EEC
3. Technical Parameter
Rated voltage: 30OV/500V
Test voltage: 2500V in accordance with DIN VDE0281 Part 2+HD21.2
Minimum bending radius fixed laying: 12.5XD (cable outer diameter)
Mobile installation: 12.5XD (cable outer diameter)
Fixed laying temperature range: -30 to+80 ℃
Mobile installation: -5 to+70 ℃
Flame retardancy: flame retardant and self-extinguishing
Complies with IEC60332-1-2+EN60332-1-2 ULvW-1+CSA FT1
Insulation resistance: 10MQ x km
4. Characteristics and Compliance
Characteristics: Solid single core wire,easy to peel,cut,easy to install,in line with the EU standard
CE Power Cord H07V-R
1. Application
Internal peripheral connecting wires between distribution boards and power distribution boards for electrical appliances and devices, as well as interfaces between electronic and electrical equipment and switchgear. Designed to use dry semi exposed and embedded conduits that can be bent several times with grounding wires.
2.Cable Structure
Conductor: Single or stranded bare copper or tinned copper wire in accordance with IEC60228VDE 0295 Class5 standard
Insulation: PVC/TI1 according to DIN VDE 0281 Part 1+HD21.1
Color code: The wire core is identified by color and complies with HD402 standard
Application standards: HD21.3 S3, VDE-0281 Part-3, CE Low Voltage Directive, 73/23/EEC, and 93/68/EEC
3. Technical Parameter
Rated voltage: 30OV/500V
Test voltage: 2500V in accordance with DIN VDE0281 Part 2+HD21.2
Minimum bending radius fixed laying: 12.5XD (cable outer diameter)
Mobile installation: 12.5XD (cable outer diameter)
Fixed laying temperature range: -30 to+80 ℃
Mobile installation: -5 to+70 ℃
Flame retardancy: flame retardant and self-extinguishing
Complies with IEC60332-1-2+EN60332-1-2 ULvW-1+CSA FT1
Insulation resistance: 10MQ x km
4. Characteristics and Compliance
Characteristics: Solid single core wire,easy to peel,cut,easy to install,in line with the EU standard
5. MOQ: 5000M
6. Data Reference
Cable Type | Cross sectional area of conductor(mm2) | Approximate wire diameter, mm | Approximate wire weight, kg/km | Maximum electrical resistance of conductor at 20 , Ohm/km, not more than |
H05V-R | 0.5 | 2 | 8.5 | 39.6 |
0.75 | 2.2 | 12 | 25.5 | |
1 | 2.3 | 14 | 21.8 | |
HO7V-R | 1.5 | 3 | 20.6 | 14 |
2.5 | 3.6 | 44.4 | 7.49 | |
4 | 4.2 | 46.8 | 4.79 | |
6 | 4.8 | 66.3 | 3.11 | |
10 | 5.9 | 109.8 | 1.99 | |
16 | 6.9 | 172.2 | 1.21 | |
25 | 8.2 | 264.5 | 0.809 | |
35 | 9.3 | 364.3 | 0.551 | |
50 | 10.8 | 515.1 | 0.394 | |
70 | 12.4 | 689 | 0.277 | |
95 | 14.5 | 958.5 | 0.203 | |
120 | 15.9 | 1175 | 0.153 | |
150 | 17.7 | 1575 | 0.124 | |
185 | 19.8 | 1945 | 0.0996 | |
240 | 22.8 | 2520 | 0.0754 |